Intermittent fault
Check the transmission control module (TCM) and transmission connectors. Check for contact resistance and oxidation according to Contact resistance and oxidation .
Check the cable between control module terminal #a47 (#a47) and transmission connector terminal #c4. Check for an intermittent open-circuit according to Open-circuit, intermittent faults .
- Check the circuit for solenoid s4. Switch off the ignition. Disconnect the control module. Measure the resistance between terminals #a47 (#a47) and #a53 (#a53) on the breakout box. The resistance must be 11-15 Ω.
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box
- To disconnect the transmission connectors, see Connectors, transmission, disconnecting / connecting
- For information about signals, see Signal description. Transmission control module (TCM) .
Select continue when the fault has been remedied.
- Continue
Refer to Information