Checking wiring and components
Check signal cable (+) between control module #A42 and heated oxygen sensor (HO2S) connector terminal #4 for a short-circuit to supply voltage according to Short-circuit to supply voltage. permanent faults , and a short-circuit to ground according to Short-circuit to ground, permanent faults .
Check signal cable (-) between control module #A41 and heated oxygen sensor (HO2S) connector terminal 3 for a short-circuit to supply voltage according to Short-circuit to supply voltage. permanent faults , and a short-circuit to ground according to Short-circuit to ground, permanent faults .
If wiring is OK, try another heated oxygen sensor (HO2S).
Remedy as necessary.
Other information
- To connect the breakout box, see connecting the breakout box
- To access/replace the heated oxygen sensor (HO2S), see Heated oxygen sensor (HO2S), replacing
- For information about signals, see Signal specification
- Continue
Refer to Verification