Intermittent Fault
Check the connector on the sun roof module (SRM) and the connector on the roof lamp module. Check for contact resistance and oxidation. Check for loose connections.
Check the cable between the sun roof module (SRM) and the roof lamp module. Check for an intermittent short-circuit to supply voltage. Check for an intermittent open-circuit.
UEM-0070 Sun roof. Faulty signal
The sun roof module (SRM) terminal #3A and roof lamp module terminal #2B.
UEM-0070 Sun roof. Faulty signal
The sun roof module (SRM) terminal #7A and roof lamp module terminal #1B.
Check the wiring between sun roof switch and RCM. Check for an intermittent short-circuit to supply voltage.
If no fault is found replace the sun roof switch. See Switch, Sun Roof, Replacing .
Other information:
- For further information about signals and other values, see Signal Specification
- To access the roof lamp module connector, see Interior Lighting, Replacing
- To access the sun roof module (SRM) connector, see Control Module, Sun Roof, Replacing
- To replace the switch for the sun roof, see Switch, Sun Roof, Replacing
- See Checking Wiring And Terminals .
- Continue
Refer to Information