Checking for open-circuits and short-circuits
Check the cable between sun roof module (SRM) terminal #10A and ground, left A-post. Check for a short-circuit to supply voltage.
Check the cable between the sun roof module (SRM) terminal #1A and fuse 11C/7 in the passenger compartment fuse box for a short-circuit to ground or an open-circuit.
Replace the cable if a fault is found.
After carrying out repairs, the sun roof module (SRM) should be calibrated. See Calibrating the sun roof module (SRM) .
Other information:
- For further information about signals and other values, see Signal specification .
- To connect the breakout box, see Connecting the breakout box .
- To access the sun roof module (SRM) connector, see Control module, sun roof, replacing .
- See Checking wiring and terminals .
Was a fault detected?
- YES
Refer to Verification
- NO
Refer to Replacing the sun roof motor