Checking wiring and connectors (3)
Check the power supply cable between upper electronic module (UEM) connector terminal #10 and movement sensor connector terminal #1. Check for an open-circuit. Check for a short-circuit to ground. Check for an intermittent open-circuit.
Other information:
- To connect the breakout box: Connecting the breakout box
- For information about upper electronic module (UEM) signals:Signal specification
- See Replacing the movement sensor
- See Checking wiring and terminals
Was a fault detected?
- YES
Refer to Verification
- NO
Refer to Checking wiring and connectors (4)