Checking for a short-circuit
Check that the button has not jammed in its depressed position.
Check the cable from the upper electronic module (UEM) to the rear reading lamp module. Check for a short-circuit to ground.
Remove the connector from the reading lamp module and measure between the connector and the upper electronic module (UEM) as follows.
UEM-0008 Right rear reading lamp
Control module terminal #20 and reading lamp module terminal #6.
UEM-0009 Left rear reading lamp
Control module terminal #20 and reading lamp module terminal #2.
Replace the cable if a fault is found.
Other information:
- For further information about signals and other values, see Signal specification
- To connect the breakout box, see Connecting the breakout box
- To access or replace the reading lamp module, see Bulb, reading lamp, rear, replacing
- To access the connector for the upper electronic module (UEM), see Interior lighting and upper electronic module (UEM), replacing
- See Checking wiring and terminals .
Was a fault detected?
- YES
Refer to Verification
- NO
FAULT NOT FOUND: Troubleshooting has been completed.