Checking for open-circuits and short-circuits
Check the cable between the upper electronic module (UEM) terminal #21 and the sun roof module (SRM) terminal #4. Check for a short-circuit to ground. Check for an open-circuit. Check for a short-circuit to supply voltage.
Remedy as necessary.
Other information
- For further information about signals and other values, see Signal specification
- To connect the breakout box, see Connecting the breakout box
- To access the sun roof control module, see Control module, sun roof, replacing
- See Checking wiring and terminals .
Was a fault detected?
- YES
Refer to Verification
- NO
FAULT NOT FOUND: Troubleshooting has been completed.