Checking the Cable
- Ignition off.
Check the cable between central electronic module (CEM) terminal #17A and relay base 2/93 terminal #2. Check for a short-circuit to supply voltage.
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the Breakout Box
- For information about signals, see Signal Specification
- See Checking Wiring And Terminals
- Continue
Refer to Verification