Checking wiring and connectors
Check the power supply cable between upper electronic module (UEM) connector terminal #10 and mass movement sensor connector terminal #1. Check for a short-circuit to supply voltage. Check for an intermittent short-circuit to supply voltage.
Other information:
- For further information about signals and other values, see Signal specification
- To connect the breakout box, see Connecting the breakout box
- To replace the movement/rear level sensor, see Replacing the movement sensor
- See Checking wiring and terminals .
- Continue
Refer to Verification