LEMON Manuals: Even more car manuals for everyone
Home >> Volvo >> 2007 >> S40 Base, 2.4 38, Automatic >> Repair and Diagnosis >> Electrical >> Body Electrical >> Switch For Start Control Unit, Frozen Values, And Status Identifier - Description (544 Body) >> Fault Tracing >> Description Of Frozen Values, Phone Module (PHM) >> Parameters, Value >> MECU Power Supply

MECU Power Supply

Measurement range 0 - 63 V.

Normal range: 12.0 - 14.5 V.

The value indicates the supply voltage to the central electronic module (CEM) when the diagnostic trouble code (DTC) was stored.