Signal Too High / Signal Missing: Verification
HINT: After carrying out the repair, check that the fault has been remedied.
- Ignition off
- Reinstall the connectors, components etc.
- Ignition on.
Activate the heater.
On activation of the heater sequence, the heater starts up and operates for approximately 2 min 30 s.
Do not interrupt the heater sequence. The heater is switched off automatically after approximately 2 min 30 s.
Read off the temperature at the overheat protection thermostat.
Check that the temperature rises when activating the heater. The temperature should cycle between outside temperature -125°C depending on the status of the heater.
Does the temperature rise?
- YES
VERIFIED: Troubleshooting has been completed.
- NO
Refer to INFORMATION