Checking Opening Using The Key: Notes
This fault-tracing assumes that the lock cylinder is not mechanically defective.
Check door control module connector A and the lock unit connector. Check for contact resistance and oxidation.
Check the cable between door control module connector terminal #A6 and lock unit connector terminal #4. Check for an open-circuit.
Check the cable between door control module connector terminal #A12 and lock unit connector terminal #1. Check for an open-circuit.
Check the cable between door control module connector terminal #A13 and lock unit connector terminal #5. Check for an open-circuit.
If no fault was found, replace the lock unit.
Other information:
- see SIGNAL SPECIFICATION
- see CONNECTING THE BREAKOUT BOX
- To access the driver/passenger door module (DDM/PDM) connector, see PASSENGER DOOR MODULE (PDM), REPLACING
- To access or replace the lock unit, see LOCK MECHANISM FRONT SIDE DOOR, REPLACING
- see CHECKING WIRING AND TERMINALS
- Continue
Refer to SYMPTOM VERIFICATION