Checking the wiring
- Ignition off.
Check the signal cable between boost pressure sensor connector terminal 3 and control module terminal 13. Check the power supply cable between boost pressure sensor terminal 1 and control module terminal 74. Check these cables for an open-circuit according to Open-circuit, permanent faults .
Check the boost pressure sensor signal cable terminal 3 to control module terminal 13 for a short-circuit to ground according to Short-circuit to ground, permanent faults .
Other information
- To connect the breakout box, see Connecting the breakout box. EMS 2000
- For information about signals, see Signal specification .
- Continue