Checking the terminal
- Ignition off
- Disconnect the connector for the camshaft position (CMP) sensor.
Check the connector for the camshaft position (CMP) sensor for contact resistance and oxidation according to Contact resistance and oxidation .
Remedy as necessary.
Was a fault detected?
- YES
Refer to Verification
- NO
Refer to Checking the signal cable