Checking injectors
- Ignition off
- Disconnect the injector connector.
Connect an ohmmeter between injector connector terminals 1 and 2.
The ohmmeter should read 14-15 Ω at 20 °C.
- OK
Refer to Defective injector
- NOT OK
Refer to Checking wiring and terminals