Checking the power cable
- Ignition off
- Disconnect the injector connector
- Ignition on.
Connect a voltmeter between injector connector terminal 1 (control module side) and ground.
The voltmeter should read battery voltage for 2 seconds immediately after the ignition is switched on.
- OK
Refer to Checking injectors
- NOT OK
Refer to Checking wiring and terminals