Checking cable and component
- Ignition off
Check the cable between boost pressure sensor 2 (MAP) terminal #3 and control module terminal #13 for short circuit to supply voltage as described in Short-circuit to supply voltage. Permanent faults .
and the cable between boost pressure sensor 2 (MAP) terminal #2 and ground for open circuit as described in Open-circuit, permanent faults .
If no fault is detected during the above fault tracing, try a new boost pressure sensor 2 (MAP) as described in Boost pressure sensor 2, replacing as necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box. EMS 2000 .
- For information on signals, see Signal specification .
Courtesy of VOLVO CARS OF NORTH AMERICA.
- Continue
Refer to Verification