Checking the cable and components
- Ignition off.
Check the cable between the boost pressure sensor terminal 3 and control module terminal 13 for a short-circuit to supply voltage according to Short-circuit to supply voltage. Permanent faults .
and the cable between boost pressure sensor terminal 2 and ground for an open-circuit according to Open-circuit, permanent faults .
If no fault is found during the above fault-tracing, try a new boost pressure sensor according to Replacing the atmospheric pressure sensor if necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box. EMS 2000
- For information about signals, see Signal specification .
Courtesy of VOLVO CARS OF NORTH AMERICA.
- Continue
Refer to Verification