Checking the wiring
- Ignition off
- Check the connectors on DSA control module terminal 5 and control module terminal 36 for contact resistance and oxidation according to Contact resistance and oxidation
- Check the signal cable between engine control module (ECM) terminal 36 and DSA control module terminal 5 for a short-circuit to ground according to Short-circuit to ground, permanent faults
- Remedy as necessary.
Other information:
- To connect the engine control module (ECM) breakout box, see Connecting the breakout box. EMS 2000
- For connecting DSA control module breakout box, see Connecting the breakout box. DSA
- For information about signals, see Signal specification .
- Continue
Refer to Verification