Checking components
- Ignition off
- Check that the air flow through the hoses from the upper rear connection on the leak diagnostic pump to the intake manifold connection (1) is unimpeded. Check that there is no leakage between the connectionsNOTE:
Air can only flow from the leak diagnostic pump to the intake manifold.
- Check the function of the non-return valve (4). See the arrow on the non-return valve
- Remedy as necessary.
Was a fault detected?
- YES
Refer to Verification
- NO
Refer to Replacing the component