Checking for an open-circuit
FENIX 5.1
- Check the cable between DSA control module terminal 5 and engine control module (ECM) terminal 41 for an open-circuit according to Open-circuit, permanent faults .
EMS 2000
- Check the cable between DSA control module terminal 5 and engine control module (ECM) terminal 36 for an open-circuit according to Open-circuit, permanent faults .
Other information
- To connect the breakout box for DSA, see Connecting the breakout box. DSA .
- To connect the breakout box for FENIX 5.1, see Connecting the breakout box. FENIX 5.1 .
- To connect the breakout box for EMS 2000, see Connecting the breakout box. EMS 2000 .
- Continue
Refer to Verification