Checking for an open-circuit and oxidation
Check the cable between breakout box terminal #50(#4) and Engine control module (ECM) terminal #B56. Check for an open-circuit, see: Checking wiring and terminals. Permanent fault
Check the ground points and connectors for contact resistance and oxidation, see: Checking wiring and terminals. Permanent fault
Was a fault detected?
- YES
Refer to Verification
- NO
Refer to Checking communication with the engine control module (ECM)