Signal too high: Verification: Verification
HINT: After carrying out the repair, check that the fault has been remedied.
- Ignition off
- Reinstall the connectors, components etc.
- Ignition on.
Read off the outside temperature in Volts. Check that it matches the value in the chart.
Temperature, °C Resistance, Ω Voltage, V 0 6318 3.99 10 3857 3.53 20 2424 3.01 30 1513 2.43 40 1034 1.96
Is the value within its permitted range?
- YES
VERIFIED: Troubleshooting has been completed.
- NO
Refer to Fault-tracing information