LEMON Manuals: Even more car manuals for everyone
Home >> Volvo >> 2004 >> S40 Base, 1.9 27 >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Ignition And Control Systems - Specifications, Electrical/Electronic (644 Body) >> Signal Description. Dynamic Stability Assist (DSA) (B4204T2 CVVT; 2000) >> DSA Signal Description

DSA Signal Description

Fig 1: DSA Control Module Terminals
GLL118762Courtesy of VOLVO CARS OF NORTH AMERICA.

All the values given below are between the terminal in column 1 and terminal 9 (ground), unless otherwise indicated in brackets.

DSA control module terminals 1 - 16 correspond to terminals 31 - 46 on the breakout box.

NOTE: It is important to connect the breakout box and check the ground terminal before taking readings.
U= DC voltage in volts (V) f = frequency in Hertz (Hz) - -
Ubat= battery voltage % duty = duty cycle (pulse ratio) as a percentage (%) - -
Ulow = voltage approximately 0 V - - - -
Terminal  Signal type  Ignition on  Engine idling  Other  Parameter read off 
#1 Power supply
(from the ignition switch)
Ubat - -
#2 Signal, wheel speed left front wheel (from the ABS control module) U ≈ 0 V - Ubat depending on the position of the wheel.
The frequency (f) increases with the speed of the wheel.
A pulsed signal (0 V - Ubat with a fixed pulse ratio (% duty ≈ 50%). -
#3 Signal, wheel speed right front wheel (from the ABS control module) U ≈ 0 V - Ubat depending on the position of the wheel.
The frequency (f) increases with the speed of the wheel.
A pulsed signal (0 V - Ubat with a fixed pulse ratio (% duty ≈ 50 %). -
#4 Signal, wheel speed left rear wheel (from the ABS control module) U ≈ 0 V - Ubat depending on the position of the wheel.
The frequency (f) increases with the speed of the wheel.
A pulsed signal (0 V - Ubat with a fixed pulse ratio (% duty ≈ 50%). -
#5 Signal, throttle position (TP) sensor
(from the engine control module (ECM))
%duty ≈ 15 % at closed throttle position (CTP) (idling).
f ≈ 50 Hz
Pulsed signal (0 V - Ubat) with fixed frequency and variable pulse ratio (% duty).
Pulse ratio (%duty) increases with increased throttle.
3
#6 Signal, DSA switch Switch unaffected:
U ≈ 0 - 3 V below Ubat
Switch affected:
U ≈Ulow
The signal is grounded when the switch is pressed. 8
#7 Signal, stop (brake) light switch Open: U ≈Ulow
Closed: U = 0 - 1.5 V below Ubat
Stop (brake) light switch closes when braking and the control module receives a signal. 11
#8 - - - -
#9 Ground (for FENIX 5.1 ground via the engine control module (ECM), measured at the battery negative terminal) Ulow - -
#10 - - - -
#11 - - - -
#12 Signal, wheel speed right rear wheel (from the ABS control module) U ≈ 0 V - Ubat depending on the position of the wheel.
The frequency (f) increases with the speed of the wheel.
A pulsed signal (0 V - Ubat with a fixed pulse ratio (% duty ≈ 50 %). -
#13 Signal, load (TQ)
(from the engine control module (ECM))
U ≈Ulow f ≈ 33 Hz Pulsed signal (0 V - Ubat) with variable frequency and pulse ratio (% duty).
The frequency increases with engine speed (RPM), the pulse ratio (%duty) increases with load.
-
#14 Diagnostic lead U = 1 - 4 V below Ubat
Other values apply if the fault-tracing instrument is connected to the data link connector (DLC).
- -
#15 Signal, request for torque limiting
(to the engine control module (ECM))
f ≈ 200 Hz Pulsed signal (0 - 5 V) with fixed frequency and variable pulse ratio (% duty). -
#16 Control signal, DSA warning lamp Lamp lit: U =0-0.5 V
Lamp not lit: Ubat
- 9, 10