LEMON Manuals: Even more car manuals for everyone
Home >> Volvo >> 2004 >> C70 2.4 63 >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Fuel, Ignition And Engine Control Systems - Specifications, Electrical/Electronic (Convertible) >> DENSO Plotter Parameters (B5244S; 2000) >> Description of parameters >> Parameters, value >> Accelerator pedal (AP) input signal, analog (V)

Accelerator pedal (AP) input signal, analog (V)

Measurement range 0-5 V.

The value is close to 0.4 V when the accelerator pedal (AP) is unaffected.