Home >> Volvo >> 2000 >> S80 Base >> Repair and Diagnosis (Single Page) >> Body & Frame >> Ignition Switch/Steering Lock >> Cables And Fuses - Symptom Related Diagnostic Procedures - 1 Of 2 >> Checking The Boot Lid Locking Function (1999-2004) >> Checking the boot lid locking function >> Checking for a short circuit

Checking for a short circuit

Check the resistance between the fuse holder secondary side (left) and ground.

The ohmmeter should display infinite resistance.

If the value is correct, replace the fuse.

NOTE: In this case the fault could be intermittent.

If the value deviates, trouble-shoot both the relay supply wire and component supply wire for a short circuit to ground as described in Short-circuit to ground, permanent faults .

HINT: Replace fuse. 

HINT: If the fuse works straight away the fault is a short circuit on the relay supply wire. 

HINT: If the fuse works when the boot lid is opened the short circuit is on the component supply wire 

HINT: Relay supply wire: fuse 11D/6 5 relay socket 2/67. 

HINT: Component supply wire: 4 relay socket 2/67 2 lock unit. 

Additional information 

Fig 1: Identifying Ohmmeter
GLL101042Courtesy of VOLVO CARS OF NORTH AMERICA.
Fig 2: Identifying Relays
GLL104090Courtesy of VOLVO CARS OF NORTH AMERICA.