Checking for an open-circuit
Check the cable between control module terminal 15 and fuse 23 in the integrated relay/fusebox for an open-circuit according to Open-circuit, permanent faults .
Select Continue when the fault has been remedied.
- Continue
Refer to Verification
Check the circuit after fuse 23 in the integrated relay/fusebox for an open-circuit according to Open-circuit, permanent faults .
- Continue