Starter No-Load Test
With starter on bench, operate starter and check ammeter, voltage and RPM. Readings should be within specification. See STARTER NO-LOAD TEST SPECIFICATIONS table.
STARTER NO-LOAD TEST SPECIFICATIONS
| Application | Volts | Amps | RPM |
|---|---|---|---|
| 0 001 108 153 | 11.5 | 75 | 2900 |
| 0 001 108 166 | 12.0 | 75 | 3000 |
| 0 001 108 167 | 12.0 | 75 | 2900 |
| 0 001 110 063 | 11.2 | 95 | 2800 |
| 0 001 111 142 | 11.5 | 75 | 2900 |
| 0 001 233 618 | 12.0 | 70 | 6100 |