Code 2-2-3: No Idle Valve Signal
- Check operation of idle valve in test mode No. 3. See TEST MODE NO. 3 under RETRIEVING CODES . If valve does not operate, check wiring.
- Connect Measuring Unit (999-3070 ) to ECU. See CONNECTING MEASURING UNIT TO ECU . Start engine. Connect voltmeter between measuring unit terminals No. 4 and 24. About 11 volts should be present. Connect voltmeter between measuring unit terminals No. 22 and 24. About 7.5 volts should be present.
- Turn engine off (ignition on). Using a voltmeter, check voltage at measuring unit terminals No. 4 and 22. Voltage should be about 8-9 volts. If no voltage is present, check wiring to idle valve.
- Turn ignition off. Using an ohmmeter, check resistance across measuring unit terminals No. 4 and 22. Resistance should be about 25 ohms. If not, replace idle valve.