LEMON Manuals: Even more car manuals for everyone
Home >> Volvo >> 1989 >> 740 GL, 4D Sedan, Standard >> Repair and Diagnosis >> Brakes >> Traction Control >> Anti-Lock Brake System >> Testing >> Ground Circuit Test >> Ground Circuits

Ground Circuits

  1. Turn ignition off. Using a DVOM, check resistance between ECU connector terminals No. 10, 20, 32 and 34 and ground. Resistance should be zero in all cases.
  2. If resistance is not correct, check wiring harness between ECU and ground connections. Circuits No. 10, 20 and 34 are grounded behind driver kickpanel. If a fault is found at terminal No. 32, test with a new solenoid valve relay. See Figure.