ATF Level, Checking: Notes
Special tools and workshop equipment required
- Used Oil Collection and Extraction Unit: SMN372500
- Oil Filler: VAS6262A
- Oil Filler - Adapter 2: VAS6262/2
- Oil Filler - Adapter 6: VAS6262/6
Note the following information:
- If ATF is filled, only use ATF that is available as a replacement part. Refer to the Parts Information.
- The : VAS6262/6 must also be used for some fluid containers.
- It may be necessary to shorten the bleed pipe on the : VAS6262A .
Shorten the Bleed Pipe on the : VAS6262A as Follows:
-- Shorten the pipe to dimension -a- so that the bleed pipe on the : VAS6262A will not touch the bottom on some fluid containers.
Dimension -a- = 210 mm
NOTE:
Dimension -a- is measured starting from the shaft of the : VAS6262A (green surface in the magnified area).
-- Shorten the bleed pipe with the : VAS6056/2 , for example.
Requirements
- The vehicle is level and all hoist mounts are the same height.
- Noise insulation removed.
- The Vehicle Diagnostic Tester is connected.
- To begin working, the oil temperature should not be higher than 45 °C (113 °F).
- Test temperature: 35 to 45 °C (95 to 113 °F)