Control Module, Attaching To Hydraulic Unit
Special Tools And Workshop Equipment Required
- ESD Work Surface:VAS6613
- Torque Screwdriver:VAG1624
- TORX® insert T25
Excessive shaking (for example, dropping, impact) may destroy the control module. The control module must then no longer be used.
- Surface must be cleaned before assembling.
-- Place the control module on the hydraulic unit without tilting.
-- Install the hydraulic unit and control module with the new included TORX® bolts switching back and forth in two steps according to the tightening specification.
The hydraulic unit threads cannot be re-cut to secure the control module. In the threads are damaged (bolts are difficult to install by hand or the bolts cannot be tightened to the tightening specification), the hydraulic unit must be replaced.
Tightening Specification
- Install the new TORX® bolts in two steps switching back and forth.
- Step 1: temporary Tightening Specification: 1 Nm to 1.5 Nm (to install the seal)
- Step 2: final Tightening Specification: 2.5 Nm
- Refer to OVERVIEW - CONTROL MODULE AND HYDRAULIC UNIT - VERSION 1
A new control module may be installed a max. of three times to a used hydraulic unit, to ensure that the elastic gasket seals sufficiently.
Do not install a used control module.