Diagnostic mode 6: Check test results of components that are not continuously monitored: Notes
NOTE:
This diagnostic mode can only be selected with Module number 10 - Engine Electronics.
Function
This diagnostic mode displays the test results of emission relevant components and systems which are not continuously monitored.
The values of the individual test results must reach the specified value or must be within the min.- and max.- limits.
| Test-ID | Component, System | Test | |||
| 01: | Catalytic converter monitoring | Refer to Test-ID 01: Catalytic converter monitoring ST-49 | |||
| 03: | Secondary Air Injection (AIR) system | Refer to Test-ID 03: Secondary Air Injection (AIR) system ST-52 | |||
| 05: | Tank ventilation system | Refer to Test-ID 05: Tank ventilation system ST-55 | |||
| 09: | Engine Coolant Temperature (ECT) Sensor -G62-1) | Refer to Test-ID 09: Engine Coolant Temperature (ECT) Sensor -G62- (vehicles with engine code BJS) ST-60 |
1) Only for vehicles with engine code BJS