Connect scan tool V.A.G 1551 and enter address word "02 Transmission electronics" and advance until "Select function XX" indicated on display. See SCAN TOOL V.A.G 1551, CONNECTING AND SELECTING FUNCTIONS  under ON BOARD DIAGNOSTIC (OBD), INITIATING.

Indicated on display:

Press keys 0 and 8. (The function "Read measuring value block" is selected with 08.)

Indicated on display:

Confirm entry with key Q.

Indicated on display:

Enter display group number. See LIST OF SELECTABLE DISPLAY GROUP NUMBERS  .

Confirm entry with key Q.

There are always 4 display zones in the measuring value block (if necessary in physical quantities):

For decoding the individual values in display zones 1 to 4, see TEST TABLE  .

If the printer is switched on, the current display is printed out on the log. If the specified values are obtained in all the display zones, press right arrow key.

Indicated on display: