Airflow Sensor Plate: Removal
Remove air filter and unscrew stop bracket. Using heat gun, heat locking compound on fastening bolt. Remove bolt slowly. Do not damage threads. Clean locking compound from bolt hole threads.
Remove air filter and unscrew stop bracket. Using heat gun, heat locking compound on fastening bolt. Remove bolt slowly. Do not damage threads. Clean locking compound from bolt hole threads.