| Enable Criteria |
Ignition is active and Air Flow Shutter "A" Control Module - Missing Message error (DTC: 0x100381) == 0 "No Error" and 8 V <= power supply <= 16 V. |
| Failure Criteria |
Active Grill Shutter (AGS) feedback for LIN response error (Interface: AGM_1_Sta_LINResp [0x31] on LIN1) == 1 "error". |
| Failure/Mature Time |
100ms |
| Pass Criteria |
Active Grill Shutter (AGS) feedback for LIN response error (Interface: AGM_1_Sta_LINResp [0x31] on LIN1) == 0 "no error". |
| Pass/De-mature Time |
200ms |
| Failure Aging |
40 driving cycles without failure |