Operating Conditions
| Enable Criteria | Wake up or Ignition ON |
| Failure Criteria | LLC Temperature greater than 86°C for 1s OR PFC Temperature greater than 86°C for 1s OR Air Temperature greater than 125°C for 1s |
| Failure/Mature Time | 1 sec |
| Pass Criteria | LLC Temperature less than 70°C for 1s AND PFC Temperature less than 70°C for 1s AND Air Temperature less than 115°C for 1s |
| Pass/De-mature Time | 1 sec |
| Failure Aging | 40 Ignition Cycles |