| Enable Criteria |
Ignition is active |
| Failure Criteria |
Signal protection calculation incorrect error is detected on Battery Management System (BMS) component (0x174, 0x176, 0x215, 0x249 on PT CAN, 0x125, 0x126, 0x209, 0x216, 0x225, 0x245, 0x248, 0x305, 0x332, 0x455 on BA CAN). |
| Failure/Mature Time |
1000 ms |
| Pass Criteria |
Signal protection calculation incorrect error is not detected on Battery Management System (BMS) messages (0x174, 0x176, 0x215, 0x249 on PT CAN, 0x125, 0x126, 0x209, 0x216, 0x225, 0x245, 0x248, 0x305, 0x332, 0x455 on BA CAN). |
| Pass/De-mature Time |
2000 ms |
| Failure Aging |
40 driving cycles without failure |