Operating Conditions
| Enable Criteria | ECU On IGN On The battery voltage is between 9V to 16V. |
| Failure Criteria | Wrong CRC is received continuously
|
| Failure/Mature Time | 500 ms |
| Pass Criteria | Message is received normally over 500 ms. |
| Pass/De-mature Time | 500 ms |
| Failure Aging | 40 Ignition cycles. |