Remote Up / Down Function does not Operate [03/2024 - ]: Procedure
- PERFORM INITIALIZATION (APPLICABLE LOCATION)
- Initialize the power window regulator motor assembly (applicable location).
Refer to REGISTRATION [12/2023 - ]
- Check that the power window operates normally by opening and closing it (applicable location).
Refer to OPERATION CHECK [03/2024 - ]
OK
Power window operates normally (applicable location).
Result
Proceed to OK NG
Result:
OK
END (PROBLEM DUE TO INITIALIZATION FAILURE)
Result:
NG
See step 2
- Initialize the power window regulator motor assembly (applicable location).
- READ VALUE USING GTS
- Using the GTS, read the data for the condition when the multiplex network master switch assembly was operated.
Body Electrical > Main Body > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note P Door Power Window UP Switch Front passenger door power window manual up switch signal OFF or ON OFF: Front passenger door power window manual up switch not being operated
ON: Front passenger door power window manual up switch being operated- RR Door Power Window UP Switch Rear RH door power window manual up switch signal OFF or ON OFF: Rear RH door power window manual up switch not being operated
ON: Rear RH door power window manual up switch being operatedfor Double Cab RL Door Power Window UP Switch Rear LH door power window manual up switch signal OFF or ON OFF: Rear LH door power window manual up switch not being operated
ON: Rear LH door power window manual up switch being operatedfor Double Cab P Door Power Window DOWN Switch Front passenger door power window manual down switch signal OFF or ON OFF: Front passenger door power window manual down switch not being operated
OFF: Front passenger door power window manual down switch not being operated- RR Door Power Window DOWN Switch Rear RH door power window manual down switch signal OFF or ON OFF: Rear RH door power window manual down switch not being operated
ON: Rear RH door power window manual down switch being operatedfor Double Cab RL Door Power Window DOWN Switch Rear LH door power window manual down switch signal OFF or ON OFF: Rear LH door power window manual down switch not being operated
ON: Rear LH door power window manual down switch being operatedfor Double Cab Window Lock Switch Window lock switch signal OFF or ON OFF: Window lock switch off (not pushed in)
ON: Window lock switch on (pushed in)- Body Electrical > Main Body > Data List
Tester Display P Door Power Window UP Switch RR Door Power Window UP Switch RL Door Power Window UP Switch P Door Power Window DOWN Switch RR Door Power Window DOWN Switch RL Door Power Window DOWN Switch Window Lock Switch OK
On the GTS screen, ON or OFF is displayed accordingly.
Result
Result Proceed to NG A OK (Front passenger door power window remote up and down functions do not operate) B OK (Rear LH door power window remote up and down functions do not operate) C OK (Rear RH door power window remote up and down functions do not operate) D
Result:
A
REPLACE MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY
Refer to REMOVAL [12/2023 - ]
Result:
B
REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY RH (for Front Door)
Refer to REMOVAL [03/2024 - ]
Result:
C
REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY LH (for Rear Door)
Refer to REMOVAL [03/2024 - ]
Result:
D
REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY RH (for Rear Door)
Refer to REMOVAL [03/2024 - ]
- Using the GTS, read the data for the condition when the multiplex network master switch assembly was operated.