Inspection [11/2015 - ]: Procedure
- INSPECT POWER SWITCH
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Power Switch)Standard Resistance
Click Location & Routing(F50)
Click Connector(F50)
Tester Connection Condition Specified Condition F50-5 (SS1) - F50-6 (AGND) Not pushed 10 kΩ or higher F50-1 (SS2) - F50-6 (AGND) Not pushed 10 kΩ or higher F50-5 (SS1) - F50-6 (AGND) Pushed Below 1 Ω F50-1 (SS2) - F50-6 (AGND) Pushed Below 1 Ω If the result is not as specified, replace the power switch.
- Apply auxiliary battery voltage between the terminals of the power switch, and check the illumination condition of the power switch indicator light.
OK
Click Location & Routing(F50)
Click Connector(F50)
Tester Connection Specified Condition F50-9 (SWIL) - Auxiliary battery positive (+)
F50-6 (AGND) - Auxiliary battery negative (-)Illuminates HINT:
- If the positive (+) lead and the negative (-) lead are incorrectly connected, the power switch indicator light will not illuminate.
- If the voltage is too low, the power switch indicator light will not illuminate.
If the result is not as specified, replace the power switch.
- Measure the resistance according to the value(s) in the table below.