Inspection [02/2017 - ]: Procedure
- INSPECT VSC OFF SWITCH (ELECTRIC PARKING BRAKE SWITCH ASSEMBLY) (for LHD)
- Check the resistance.
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(VSC OFF Switch (Electric Parking Brake Switch Assembly))Standard Resistance
Tester Connection Condition Specified Condition 13 (+) - 8 (E) Switch pushed Below 1 Ω 13 (+) - 8 (E) Switch not pushed 10 kΩ or higher If the result is not as specified, replace the VSC OFF switch (electric parking brake switch assembly).
- Measure the resistance according to the value(s) in the table below.
- Check the resistance.
- INSPECT VSC OFF SWITCH (ELECTRIC PARKING BRAKE SWITCH ASSEMBLY) (for RHD)
- Check the resistance.
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(VSC OFF Switch (Electric Parking Brake Switch Assembly))Standard Resistance
Tester Connection Condition Specified Condition 11 (+) - 8 (E) Switch pushed Below 1 Ω 11 (+) - 8 (E) Switch not pushed 10 kΩ or higher If the result is not as specified, replace the VSC OFF switch (electric parking brake switch assembly).
- Measure the resistance according to the value(s) in the table below.
- Check the resistance.