Power Switch: Inspection: Inspection
- INSPECT POWER SWITCH
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition 5 (SS1) - 6 (AGND) Pushed Below 1 Ω 1 (SS2) - 6 (AGND) Pushed Below 1 Ω 5 (SS1) - 6 (AGND) Not pushed 10 kΩ or higher 1 (SS2) - 6 (AGND) Not pushed 10 kΩ or higher If the result is not as specified, replace the power switch.
- Apply battery voltage between the terminals of the switch, and check the illumination condition of the power switch.TEXT IN ILLUSTRATION
*a Power Switch Illumination - - Standard Resistance
Measurement Condition Specified Condition Auxiliary battery positive (+) →Terminal 9 (SWIL)
Auxiliary battery negative (-) →Terminal 6 (AGND)Illuminates
(Power Switch Illumination)If the result is not as specified, replace the power switch.
- Measure the resistance according to the value(s) in the table below.