Heated Oxygen Sensor: Inspection: Inspection
- INSPECT HEATED OXYGEN SENSOR
- Measure the resistance according to the value(s) in the table below.TEXT IN ILLUSTRATION
*a Component without harness connected:
(Heated Oxygen Sensor)*b for Bank 1: *c for Bank 2: Standard Resistance (for Bank 1)
Tester Connection Condition Specified Condition 1 (HT1B) - 2 (+B) 20°C (68°F) 11 to 16 Ω 1 (HT1B) - 4 (E2) Always 10 kΩ or higher Standard Resistance (for Bank 2)
Tester Connection Condition Specified Condition 1 (HT2B) - 2 (+B) 20°C (68°F) 11 to 16 Ω 1 (HT2B) - 4 (E2) Always 10 kΩ or higher If the result is not as specified, replace the sensor.
- Measure the resistance according to the value(s) in the table below.