Emission Control System (1AR-FE) (Service Information): Canister: Installation: Installation
- INSTALL CHARCOAL CANISTER ASSEMBLY
- Connect the charcoal canister assembly with the 3 nuts.
Torque: 5.5 N*m (56 kgf*cm, 49 in.*lbf)
- Align the quick connector with the pipe, then push in the quick connector until the retainer makes a "click" sound to connect the charcoal canister fuel hose to the charcoal canister assembly.
NOTE:
- Check that there are no scratches or foreign objects around the connected part of the quick connector and pipe before this work.
- After connecting the charcoal canister fuel hose, confirm that it is securely connected by pulling the quick connector.
- Connect the hose.
- Connect the hose and connector.
- Connect the charcoal canister assembly with the 3 nuts.
- INSTALL NO. 3 FRONT FLOOR HEAT INSULATOR
- Install the No. 3 front floor heat insulator with the 4 bolts.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
Torque: 4.9 N*m (50 kgf*cm, 43 in.*lbf)
- Install the No. 3 front floor heat insulator with the 4 bolts.
- INSTALL CENTER EXHAUST PIPE ASSEMBLY . Refer to INSTALLATION - Step 3
- INSTALL TAIL EXHAUST PIPE ASSEMBLY . Refer to INSTALLATION - Step 5
- INSPECT FOR EXHAUST GAS LEAK