Service Data
THERMOSTAT
| Condition | Specified Condition |
|---|---|
| Standard valve opening temperature | 80 to 84 °C (176 to 183 °F) |
| Standard valve lift | 10 mm (0.39 in.) or more at 95 °C (203 °F) |
COOLING FAN MOTOR
| Item | Condition | Specified Condition |
|---|---|---|
| No. 1 cooling fan motor | 20 °C (68 °F) | 11.8 to 14.8 A |
| No. 2 cooling fan motor | 20 °C (68 °F) | 9 to 11 A |
COOLING FAN ECU
| Condition | Specified Condition |
|---|---|
| Turn the Ignition switch to the ON position | 9 to 14 V |
COOLING FAN RELAY
| Tester Connection | Specified Condition |
|---|---|
| 3 - 5 | 10 kΩor higher |
| 3 - 5 | Below 1 Ω (when battery voltage is applied to terminals 1 and 2) |
RADIATOR
| Item | Condition | Specified Condition |
|---|---|---|
| Radiator reservoir cap | For brand-new cap | 93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2 , 13.5 to 17.8 psi) |
| After using cap | 78.5 kPa (0.8 kgf/cm2 , 11.4 psi) |