| Front speed sensor |
for BOSCH |
LH |
1 (FL+) - 2 (FL-) |
Always |
0.92 to 1.22 kΩ at 20 °C(68°F) |
| 1 (FL+) - Body ground |
Always |
10 kΩ or higher |
| 2 (FL-) - Body ground |
Always |
10 kΩ or higher |
| RH |
1 (FR+) - 2 (FR-) |
Always |
0.92 to 1.22 kΩ at 20 °C(68°F) |
| 1 (FR+) - Body ground |
Always |
10 kΩ or higher |
| 2 (FR-) - Body ground |
Always |
10 kΩ or higher |
| for ADVICS |
LH |
1 (FL+) - 2 (FL-) |
Always |
1.4 to 1.8 kΩ at 20°C (68 °F) |
| 1 (FL+) - Body ground |
Always |
10 kΩ or higher |
| 2 (FL-) - Body ground |
Always |
10 kΩ or higher |
| RH |
1 (FR+) - 2 (FR-) |
Always |
1.4 to 1.8 kΩ at 20°C (68 °F) |
| 1 (FR+) - Body ground |
Always |
10 kΩ or higher |
| 2 (FR-) - Body ground |
Always |
10 kΩ or higher |
| Skid control sensor |
for BOSCH |
LH |
1 (RR+) - 2 (RR-) |
Always |
Below 2.2 kΩ |
| 1 (RR+) - Body ground |
Always |
10 kΩ or higher |
| 2 (RR-) - Body ground |
Always |
10 kΩ or higher |
| RH |
1 (RL+) - 2 (RL-) Below |
Always |
Below 2.2 kΩ |
| 1 (RL+) - Body ground 10 |
Always |
10 kΩ or higher |
| 2 (RL-) - Body ground |
Always |
10 kΩ or higher |
| for ADVICS |
LH |
2 (RL+) - 1 (RL-) |
Always |
0.9 to 2.1 kΩ |
| 2 (RL+) - Body ground |
Always |
10 kΩ or higher |
| 1 (RL-) - Body ground |
Always |
10 kΩ or higher |
| RH |
2 (RR+) - 1 (RR-) |
Always |
0.9 to 2.1 kΩ |
| 2 (RR+) - Body ground |
Always |
10 kΩ or higher |
| 1 (RR-) - Body ground |
Always |
10 kΩ or higher |
| VSC NO. 1 (Fail Safe) relay |
|
|
Resistance 3 - 5 |
Always |
10 kΩ or higher |
| Resistance 3 - 5 |
Apply B+ between terminals 1 and 2 |
Below 1 Ω |
| VSC NO. 1 relay |
|
|
Resistance 3 - 5 |
Always |
10 kΩ or higher |
| Resistance 3 - 5 |
Apply B+ between terminals 1 and 2 |
Below 1 Ω |
| VSC OFF switch |
|
|
Resistance 6 - 3 |
Switch is pushed in |
Below 1 Ω |
| |
|
Resistance 6 - 3 |
Switch is not pushed in |
10 kΩ or higher |