Typical Enabling Conditions
Functional check:
TYPICAL ENABLING CONDITIONS
| Monitor runs whenever following DTCs not present | P0010 (VVT OCV) P0011 (VVT system 1 - advance) P0012 (VVT system 1 - retard) P0016 (VVT system 1 - misalignment) P0031 - P0032 (A/F sensor heater) P0100 - P0103 (MAF meter) P0115 - P0118 (ECT sensor) P0120 - P0223, P2135 (TP sensor) P0125 (Insufficient ECT for closed loop) P0171, P0172 (Fuel system) P0301 - P0304 (Misfire) P0335 (CKP sensor) P0340 (CMP sensor) P0351 - P0354 (Ignitor) P0500 (VSS) P2195, P2196 (A/F sensor) P2237 - P2253 (A/F sensor) P2A00 (A/F sensor) |
| Engine | Running |
Range check:
TYPICAL ENABLING CONDITIONS
| Time after first missing voltage change | 10 seconds or more |
| Output signal duty | 10 to 90% |
| Battery voltage | 11 V or more |