LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2009 >> Yaris Base, 2D Hatchback, Automatic >> Repair and Diagnosis >> Engine Mechanical >> Auxiliary Emission Control Systems >> Canister >> Inspection

Auxiliary Emission Control Systems: Canister: Inspection

  1. INSPECT CANISTER 
    1. Visually check the canister for cracks and damage.

      If cracks or damage are found, replace the canister.

      Fig 1: Locating Canister Connection
      G04829132Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Check the canister operation.
      1. While holding the purge port closed, blow air at 0.39 kPa (4.0 kgf/cm2 , 3 mmHg) into the vent port, and check that air flows from the air inlet port.

        If the result is not as specified, replace the canister.

        Fig 2: Checking If Air Flows From Air Inlet Port
        G04829133Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      2. While holding the air inlet port closed, blow air at 0.39 kPa (4.0 kgf/cm2 , 3 mmHg) into the vent port, and check that air flows from the purge port.

        If the result is not as specified, replace the canister.

        Fig 3: Checking If Air Flows From Purge Port
        G04829134Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      3. While holding the air inlet port closed, apply vacuum at 3.43 kPa (35.0 kgf/cm2 , 25.7 mmHg) into the vent port, and check that air is sucked into the purge port.

        If the result is not as specified, replace the canister.

        Fig 4: Checking If Air Is Sucked Into Purge Port
        G04829135Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    3. Check the air tightness.
      1. While holding the vent and air inlet ports closed, apply vacuum at 3.43 kPa (35.0 kgf/cm2 , 25.7 mmHg) into the purge port, and check that the vacuum is maintained for 1 minute.

        If the result is not as specified, replace the canister.

        Fig 5: Checking Air Tightness
        G04829136Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    4. Check the diaphragm.
      1. Remove the air hose between ports A and B.
      2. While holding the vent, purge and air inlet ports closed, apply vacuum at 1.42 kPa (14.5 kgf/cm2 , 10.6 mmHg) into port A, and check that air is not sucked into port B.
        Fig 6: Checking If Air Is Not Sucked Into Port B
        G04829137Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      3. While holding the vent, purge and air inlet ports closed, apply vacuum at 1.42 kPa (14.5 kgf/cm2 , 10.6 mmHg) into port A, and measure how long it takes for the vacuum to drop.

        Vacuum drop time: 

        10 seconds or more 

        If the result is not as specified, replace the canister.

        Fig 7: Applying Vacuum Into Port A
        G04829138Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    5. Check the leak detection pump.
      1. Check that air flows from port A to ports B and C.

        If the result is not as specified, replace the canister.

        Fig 8: Checking If Air Flows From Port A To Ports B & C
        G04829139Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      2. Connect the positive (+) lead of the battery to terminal 7 and the negative (-) lead to terminal 6.
      3. Check that the valve is closed.

        If the result is not as specified, replace the canister.

      4. Install the canister pump module.
        Fig 9: Identifying Canister Pump Module Connector Terminals
        G04829140Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002