Vacuum switching valve assembly
VACUUM SWITCHING VALVE ASSEMBLY SERVICE DATA
| Tester Connection | Specified Condition |
|---|---|
| 1-2 | 37 to 44 Ω at 20°C (68°F) |
| 1 - Body ground 2 - Body ground |
1 MΩ or higher |
Compression spring
COMPRESSION SPRING SERVICE DATA
| Front exhaust pipe assembly x Exhaust manifold converter sub-assembly | Minimum length: 41.5 mm (1.64 in.) |
|---|---|
| Center exhaust pipe assembly x Front exhaust pipe assembly | Minimum length: 38.5 mm (1.52 in.) |